7SR220 Settings Guide
Unrestricted Page 64 of 107 © 2013 Siemens Protection Devices Limited
Description Range Default
Ext Reset 60VTS
Selects which inputs reset the VT Supervision element
Combination of ( BI1, BI2, BI3, BI4,
BI5, BI6, BI7, BI8, BI9, BI10, BI11,
BI12, BI13, V1, V2, V3, V4, V5, V6,
V7, V8, V9, V10, V11, V12, V13,
V14, V15, V16 )
----------------------
-------
Inhibit 60VTF-Bus
Selects which inputs inhibit the 60VTF-Bus Supervision
element
Combination of ( BI1, BI2, BI3, BI4,
BI5, BI6, BI7, BI8, BI9, BI10, BI11,
BI12, BI13, V1, V2, V3, V4, V5, V6,
V7, V8, V9, V10, V11, V12, V13,
V14, V15, V16 )
----------------------
-------
Reset CB Total Trip
Selects which inputs Reset the CB Total Trip count
Combination of ( BI1, BI2, BI3, BI4,
BI5, BI6, BI7, BI8, BI9, BI10, BI11,
BI12, BI13, V1, V2, V3, V4, V5, V6,
V7, V8, V9, V10, V11, V12, V13,
V14, V15, V16 )
----------------------
-------
Reset CB Ph A Count
Selects which inputs Reset the CB Ph A Count
Combination of ( BI1, BI2, BI3, BI4,
BI5, BI6, BI7, BI8, BI9, BI10, BI11,
BI12, BI13, V1, V2, V3, V4, V5, V6,
V7, V8, V9, V10, V11, V12, V13,
V14, V15, V16 )
----------------------
-------
Reset CB Ph B Count
Selects which inputs Reset the CB Ph B Count
Combination of ( BI1, BI2, BI3, BI4,
BI5, BI6, BI7, BI8, BI9, BI10, BI11,
BI12, BI13, V1, V2, V3, V4, V5, V6,
V7, V8, V9, V10, V11, V12, V13,
V14, V15, V16 )
----------------------
-------
Reset CB Ph C Count
Selects which inputs Reset the CB Ph C Count
Combination of ( BI1, BI2, BI3, BI4,
BI5, BI6, BI7, BI8, BI9, BI10, BI11,
BI12, BI13, V1, V2, V3, V4, V5, V6,
V7, V8, V9, V10, V11, V12, V13,
V14, V15, V16 )
----------------------
-------
Reset CB E/F Count
Selects which inputs Reset the CB E/F Count
Combination of ( BI1, BI2, BI3, BI4,
BI5, BI6, BI7, BI8, BI9, BI10, BI11,
BI12, BI13, V1, V2, V3, V4, V5, V6,
V7, V8, V9, V10, V11, V12, V13,
V14, V15, V16 )
----------------------
-------
Reset CB Delta Trip
Selects which inputs Reset the CB Delta Trip count
Combination of ( BI1, BI2, BI3, BI4,
BI5, BI6, BI7, BI8, BI9, BI10, BI11,
BI12, BI13, V1, V2, V3, V4, V5, V6,
V7, V8, V9, V10, V11, V12, V13,
V14, V15, V16 )
----------------------
-------
Reset ARBlock Count
Selects which inputs Reset the AR Block count
Combination of ( BI1, BI2, BI3, BI4,
BI5, BI6, BI7, BI8, BI9, BI10, BI11,
BI12, BI13, V1, V2, V3, V4, V5, V6,
V7, V8, V9, V10, V11, V12, V13,
V14, V15, V16 )
----------------------
-------
Reset Freq Ops Count
Selects which inputs Reset the Frequent Ops count
Combination of ( BI1, BI2, BI3, BI4,
BI5, BI6, BI7, BI8, BI9, BI10, BI11,
BI12, BI13, V1, V2, V3, V4, V5, V6,
V7, V8, V9, V10, V11, V12, V13,
V14, V15, V16 )
----------------------
-------
Reset I^2t CB Wear
Selects which inputs Reset the I^2t CB Wear element
Combination of ( BI1, BI2, BI3, BI4,
BI5, BI6, BI7, BI8, BI9, BI10, BI11,
BI12, BI13, V1, V2, V3, V4, V5, V6,
V7, V8, V9, V10, V11, V12, V13,
V14, V15, V16 )
----------------------
-------
Trigger I^2t CB Wear
Selects which inputs will cause an external trigger of the I^2t
CB Wear element
Combination of ( BI1, BI2, BI3, BI4,
BI5, BI6, BI7, BI8, BI9, BI10, BI11,
BI12, BI13, V1, V2, V3, V4, V5, V6,
V7, V8, V9, V10, V11, V12, V13,
V14, V15, V16 )
----------------------
-------
Reset Trip Time
Selects which inputs will reset the CB trip time alarm
Combination of ( BI1, BI2, BI3, BI4,
BI5, BI6, BI7, BI8, BI9, BI10, BI11,
BI12, BI13, V1, V2, V3, V4, V5, V6,
V7, V8, V9, V10, V11, V12, V13,
V14, V15, V16 )
----------------------
-------