2.10 System interfaces
Trunk interface with analogue trunk
DTMF, DP without earth recall
Tone detector (dial-tone interpreter) for automatic dialling
Analogue pseudo direct dialling in using DTMF signalling with announcement (DDI option)
Call-charge pulse recognition per trunk (GEE option)
Fax option
Mixed fax/DDI operation (option)
Trunk interface with direct dialling in for Austria
WS48 and ÜFS methods
Trunk interface and extension interface S
0
System synchronisation to trunk clock with selection circuit
Extension interface for normal telephone
Bilingual: DP or DTMF (12-key keyboard)
Range 2000 m using cable with 0.6 mm dia
Flash detection with DTMF
One or more entrance telephone adaptors can be connected
Extension interface for U
P0/E
Only in-house cabling permitted
Hicom 108 Hicom 112 Hicom 118
U
P0/E
interfaces - MB 2 4 6
a/b interfaces - MB 4 4 4
Slots for expansions 1 2 4
Table 2-5 Basic configuration and system expansions