No. Parameter
mask
Parameter
internal
Data type Meaning
39 <S_AMODE2
>
INT Alternative mode 2
UNITS: UNITS: Drilling feedrate F
0 = F/min
1 = F/rev
TENS: Evaluation of predrilling feedrate FA
0 = As % of drilling feedrate
1 = F/min
2 = F/rev
HUNDREDS: Evaluation of feedrate for travel into pilot
hole FP
0 = As % of drilling feedrate
1 = F/min
2 = F/rev
THOUSANDS: Evaluation of first cut feedrate FS
0 = As % of drilling feedrate
1 = F/min
2 = F/rev
TEN THOUSANDS: Evaluation of through-drilling feedrate FD
0 = As % of drilling feedrate
1 = F/min
2 = F/rev
HUNDRED THOUSANDS: Retraction feedrate FR
0 = F/min
1 = Rapid traverse
ONE MILLION: Drilling - spindle speed / cutting rate
(S/V5)
0 = Constant spindle speed
1 = Constant cutting rate
TEN MILLIONS: Approach with spindle speed / cutting
rate (SP/V4)
0 = Constant spindle speed
1 = Constant cutting rate
2 = Spindle speed in % of the drilling
speed
HUNDRED MILLIONS: Retraction - spindle speed / cutting rate
(SR/V6)
0 = Constant spindle speed
1 = Constant cutting rate
2 = Spindle speed in % of the drilling
speed
Work preparation
3.25 Programming cycles externally
NC programming
1106 Programming Manual, 12/2019, 6FC5398-2EP40-0BA0