No. Parameter
mask
Parameter
internal
Data type Meaning
40 <S_AMODE3
>
INT Alternative mode 3
UNITS: Drilling depth ZA abs/inc
0 = Incremental
1 = Absolute
TENS: Depth of the pilot hole ZP
0 = Incremental
1 = Absolute
2 = Factor of the hole diameter
HUNDREDS: Remaining drilling depth ZD abs/inc
0 = Incremental
1 = Absolute
41 ZPV <S_ZPV> REAL Incremental limit distance from pilot hole depth
3.25.1.38 CYCLE832 - High-Speed Settings
Syntax
CYCLE832(<S_TOL>, <S_TOLM>, <S_OTOL>)
Note
CYCLE832 does not relieve the machine manufacturer from optimization tasks that are
necessary when commissioning the machine. This involves the optimization of the axes
involved in the machining process and NCU settings (precontrol, jerk limiting, etc.).
Work preparation
3.25 Programming cycles externally
NC programming
Programming Manual, 12/2019, 6FC5398-2EP40-0BA0 1107