Information for the CANopen master Issue 01/05
CANopen Option Module Operating Instructions
106 6SE6400-5BC00-0BP0
6.2 Parameter "P0927" – change source for parameters
This parameter can be set in order to define the sources of the parameter changes.
Bit 0 CANopen master 0: No
1: Yes
Bit 1 BOP 0: No
1: Yes
Bit 2 Mounting set PC/drive converter
(USS at the BOP interface)
0: No
1: Yes
Bit 3 Local RS485 interface (terminal 14/15
(MICROMASTER 420) and 29/30
(MICROMASTER 440) with USS)
0: No
1: Yes
The pre-setting (default setting) for all bits is 1; this means that the parameters of
all of the sources can be changed.