6-9
History Log
password change originated on an MKB-4
at address 251. The division sign indicates
that this is a history log display.
PASSWORD LEVEL : 1
The message that describes this as a
password event and indicates the new
password authorization level that was
entered.
4214
The history log sequence number.
11:25:14 Mar 11, 20XX
The time that the event was logged.
Configuration Changed Event
This event occurs when an operator
uploads a new CSG-M configuration to the
MXL-IQ control panel. The LCD displays:
254254
254254
254÷
Configuration changed 10->11 Configuration changed 10->11
Configuration changed 10->11 Configuration changed 10->11
Configuration changed 10->11
4214 11:25:14 Mar 11,20XX4214 11:25:14 Mar 11,20XX
4214 11:25:14 Mar 11,20XX4214 11:25:14 Mar 11,20XX
4214 11:25:14 Mar 11,20XX
Where:
254÷
The module addres where the configuration
change occurred. In this example, the
configuration change originated from the
field programmer at address 254. The
division sign indicates that this is a history
log display.
Configuration changed
The message that describes this as a
configuration change event.
10
The old configuration modification se-
quence number.
11
The new configuration modification se-
quence number.
Note: These values may not be consecu-
tive. They depend on the number of modifi-
cations made to the configuration by the
CSG-M.
4214
The history log sequence number.
11:25:14 Mar 11, 20XX
The time that the event was logged.
Manual Sensitivity Set Event
A sensitivity set event displays any change
of sensitivity to a detector device that was
made manually at a system control panel.
The LCD displays:
001001
001001
001÷
001 1ST FLOOR EAST WING NORMAL001 1ST FLOOR EAST WING NORMAL
001 1ST FLOOR EAST WING NORMAL001 1ST FLOOR EAST WING NORMAL
001 1ST FLOOR EAST WING NORMAL
321 12:24:48 Mar 10,1995321 12:24:48 Mar 10,1995
321 12:24:48 Mar 10,1995321 12:24:48 Mar 10,1995
321 12:24:48 Mar 10,1995
Where:
001÷001
The module/device address. The division
sign indicates that this is a history log
display.
1ST FLOOR EAST WING
The custom message assigned to this input.
321
The history log sequence number.
12:24:48 Mar 10, 20XX
The time that the event was logged.
NORMAL
The sensitivity value sent to the device. The
selectable values include:
Hi_3
Hi_2
Hi_1
NORMAL
Low_1
Low_2
Low_3
Auto Sensitivity Set Event
A sensitivity set event displays any change
of sensitivity to a detector device made by
the auto sensitivity adjustment system. The
LCD displays:
001001
001001
001÷
001 1ST FLOOR EAST WING 2.12 +001 1ST FLOOR EAST WING 2.12 +
001 1ST FLOOR EAST WING 2.12 +001 1ST FLOOR EAST WING 2.12 +
001 1ST FLOOR EAST WING 2.12 +
321 12:24:38 Mar 10, 20XX321 12:24:38 Mar 10, 20XX
321 12:24:38 Mar 10, 20XX321 12:24:38 Mar 10, 20XX
321 12:24:38 Mar 10, 20XX
Where:
001÷001
The module/device address. The division
sign indicates that this is a history log
display.
1ST FLOOR EAST WING
The custom message assigned to this
input.