19.3.5 Unreset Counter
[TM35] Unreset Counter This menu shows the number of alarm who have occurred from the beginning. This counter can't be reset,
except with a factory reset.
19.4 Engineer Reset
These functions are explained in the menu
12"System".
19.5 System Programming
These functions are explained in the menu
12"System".
19.6 Telecom Options
These functions are explained in the menu
13 "ARC".
19.7 Time Functions
These functions are explained in the menu
3"Miscellaneous".
19.8 Tests
19.8.1 Walk Test
[TM81] Walk test This menu function enables a walk test to be carried out in the individual partitions. The walk test activates
the walk test outputs. In the event of a walk test alarm the buzzer or internal bell, as selected, is activated
briefly. A walk test can naturally only be carried out with the inputs which are unset. Set inputs, e.g. inputs
monitored for 24 hours, immediately trigger a real alarm. Otherwise, the line test must used.
Partitions The walk test is carried out per partition.
Buzzer activation This parameter allows not only the buzzer to be briefly activated during the walk test, but also the internal
bell.
Walk test outputs During the walk test, all the outputs programmed for the walk test in this partition are activated.
[TM52] Delete storing
messages outputs
After a walk test alarm, all the outputs in this partition programmed as "Delete storing messages" are briefly
activated.
Timeout The walk test is limited to 2 hours by a timeout.
19.8.2 Input Test
[TM82] Test of inputs This menu function enables each individual input in the individual partitions to be tested. By means of this
test, the actual state or triggering and resetting can be tested. By storing or transfers from idle to the trig-
gered state or the other way round, individual inputs can be triggered locally and subsequently checked by
triggering at the central control unit. The input which is on test is switched off during the test, e.g. it does not
trigger a real alarm but instead only the status is indicated on the LCD display and the buzzer or inner bell is
briefly activated as chosen. The resistance value or the quality of the radio transmission is also indicated.
Partitions The choice of partition limits the test to this partition.
Buzzer activation This parameter enables not only the buzzer to be briefly activated during a walk test but also the internal bell.
Actual state The actual state of the input is indicated on the LCD keypad.
Stored information The changeover from idle state to the triggered state or the other way round is shown in the display.
Reset The stored information can be deleted by pressing the X key, which also causes the test of this input to be
halted. If the test of this input is to be continued, this input must again be confirmed.
Symbols The states or change of states are indicated as follows. (useful for single person testing)
= Input actually in idle state,
= Input actually in triggered state,