System
68
Siemens Building Technologies
Fire Safety & Security Products 07.2009
12.10 Print Style
Disable The specific separator is disabled for log logbook printing.
The CR/LF is is used to separate fields.
Enable A specific separator is used for logbook printing.
CR/LF is replaced by #.
Examples:
266#30/06/20 10:56:47# > #TROUBLE #INITIALISATION
267#30/06/20 10:57:03# > #BEGIN #LOCAL ACCESS
268#30/06/20 10:57:04# > #END #LOCAL ACCESS
269#30/06/20 10:57:12# > #BEGIN ALARM #I1/MAIN PCB #INPUT 1
270#30/06/20 10:57:16# > #END ALARM #I1/MAIN PCB #INPUT 1
12.11 Flow Events Sort
[TM5178] Print This parameter is only accessible via keypad.
It can be used to sort / filter events stored in log book . Possible filter are:
z Alarms
z Set / Unset
z Transmission
z Tamper
z Trouble
12.12 Engineer Reset on
[TM4] Alarm Types This parameter defines how the engineer reset works on the system. You can choose between Tamper-,
Burglar- and Panic alarm.
z Tamper alarms
z Burglar alarm
z Panic alarms
NOTE
You have to activate it for each partition separately in the menu partitions.