15 Input Transmission
[TM66] Transmission
lines
Every transmission can be programmed individually per Input and receiver.
1 - 48: Physical inputs The individual physical inputs can be transmitted according to the protocol. To do this, the code is deter-
mined from the input type for protocols with a fixed code assignment. Otherwise the code or channel can
be chosen as required. The inputs are transmitted on triggering. A clear message is sent on return to the
idle state.
49 - 55: PA Keypad The panic alarm of the individual keypads can be transmitted, depending on the protocol. To do this, the
code is determined from the line type for protocols with a fixed code assignment. Otherwise the code or
channel can be chosen as required.
56: System Tamper Is transmitted on a system tamper alarm. The following are regarded as internal system tamper.
z Open central control unit or E-bus components
z Loss of E-bus components
z Internal Tamper alarm ( i.e. SAT12)
57: Mains Failure Is transmitted in the event of a mains fault in the central control unit or one of the external power supply
assemblies. Clear message when fault ends.
58: Bat/Fus Failure Is transmitted in the event of a battery fault in the central control unit or one of the external power supply
assemblies. Clear message when fault ends.
15.1 Transmission CMS/ARC 1 & 2
Transmission with a protocol (Menu ARC parameter “protocol”)
No Transmission The input won’t be transmitted.
When a transmission is chosen, define the following parameters.
Alarm Code Alarm code depend on the chosen protocol.
Invert Beg/Rest Invert the alarm and the restore event for the ARC.
Transm. to CMS/ARC
Transmission
Restore to CMS/ARC Sending an event to the ARC, when the alarm is off again.
Transmission without a protocol, Vocal (Menu ARC parameter “protocol”)
No Transmission The input won’t be transmitted.
When a transmission is chosen, define the following parameters.
Transm. to CMS/ARC
Transmission
Message Alarm messages 1
to 6 can be chosen.
NOTE
The Alarm and the Help messages can be
recorded according to the Engineer menu
“Recording of messages”