Partitions
54
Siemens Building Technologies
Fire Safety & Security Products 07.2009
Example with Keypad
(SI220 only)
Keypad LCD display show :
PARTITION2
MSMMMMMMMMMMMMMM
--> Partition 2 is Sub-Partition(S), all others are Main Partitions (M)
After Entering Partition 2 the LCD display shows:
S.02 DEP. M01
D * - - D - - - - - - - - - - - - -
--> Sub-Partition 02 is depending on Main Partitions 01 and 05
9.3 Allowed Keypads
Partition Authorization
for Remote Keypads
Every remote keypad can be assigned to any main partition. This enables the remote keypads to have ac-
cess to individually specified partitions only.
Keypad X = Keypad No X has access to this partition
- = Keypad No X has no access
9.3.1 All Keypads in Part Set
Status Display of Re-
mote Keypads
Active = All indicators and keys active.
9.3.2 All Keypads when Unset
Status Display of Re-
mote Keypads
Inactive = All indicators and keys inactive, only the date and time are shown. Note that in this case
no control can be exercised from the remote keypad, i.e. an input has to be programmed for un
setting and otherwise the partition can no longer be unset.
9.3.3 All Keypads in Full Set
Status Display of Re-
mote Keypads
PIN + LCD = Only the keys for the PIN input and LCD are enabled. The LED displays are blocked.
The buzzer is activated on the delay time. This is then chosen if the continued presence of an alarm is
not to be indicated. -> (No alarm is displayed)
9.4 External Bell
9.4.1 When Part Set
External Bell on Part Set
All other country ver-
sions
This parameter defines whether the external bell is enabled or not in the event of a burglar alarm on part set.
This parameter also acts on the strobe light output.
Yes = Enabled
No = Disabled
(IT) This country version is the same as above, but in addion a Panic in unset also activates the external bell if
enabled for part set.
9.4.2 Duration
External Bell Duration This parameter defines the maximum triggering time of the external bell outputs in the event of an alarm.
Any time from 001 to 127 seconds or minutes can be entered (000 = continuous).
This timer runs only for outputs with logical type “External Bell”.