Data Blocks/Error Lists
C-5
FM 351 Positioning Module
C79000-G7076-C351-02
Table C-1 Content of the Channel DB
Address DescriptionInitial
Value
Data
Type
Name
Done Bits for Write Jobs
39.0 MDWR_D BOOL FALSE 1 = “write machine data” job
completed
39.1 MD_D BOOL FALSE 1 = “activate machine data” job
completed
39.2 DELDIST_D BOOL FALSE 1 = “delete remaining distance” job completed
39.3 AVALREM_D BOOL FALSE 1 = “cancel set actual value” job
completed
39.4 TRGL1WR_D BOOL FALSE 1 = “write incremental dimension table 1” job
completed
39.5 TRGL2WR_D BOOL FALSE 1 = “write incremental dimension table 2” job
completed
39.6 REFPT_D BOOL FALSE 1 = “set reference point” job
completed
39.7 AVAL_D BOOL FALSE 1 = “set actual value” job completed
40.0 FVAL_D BOOL FALSE Not used
40.1 ZOFF_D BOOL FALSE Not used
40.2 TRG252_254_D BOOL FALSE 1 = “write incremental dimension for incremental
dimension number
254” completed
40.3 TRG255_D BOOL FALSE 1 = “write incremental dimension for incremental
dimension number
255” completed
40.4 DELDIAG_D BOOL FALSE 1 = “delete diagnostic buffer” job
completed
Done Bits for Read Jobs
40.5 MDRD_D BOOL FALSE 1 = “read machine data” job
completed
40.6 TRGL1RD_D BOOL FALSE 1 = “read incremental dimension table 1” job
completed
40.7 TRGL2RD_D BOOL FALSE 1 = “read incremental dimension table 2” job
completed
41.0 MSRRD_D BOOL FALSE Not used
41.1 ACTSPD_D BOOL FALSE 1 = “read actual speed, remaining distance and
current incremental dimension” job
completed
41.2 ENCVAL_D BOOL FALSE 1 = “read encoder values” job completed