Data Blocks/Error Lists
C-6
FM 351 Positioning Module
C79000-G7076-C351-02
Table C-1 Content of the Channel DB
Address DescriptionInitial
Value
Data
Type
Name
Error Bits for Function Switches
42.0 PLOOP_ERR BOOL FALSE 1 = error in loop traverse in
direction plus job
42.1 MLOOP_ERR BOOL FALSE 1 = error in loop traverse in
direction minus job
42.2 EI_ERR BOOL FALSE 1 = error in Do not evaluate enable input job
42.3 EDGE_ERR BOOL FALSE Not used
42.4 MSR_ERR BOOL FALSE Not used
Error Bits for Write Jobs
43.0 MDWR_ERR BOOL FALSE 1 = error in write machine data job
43.1 MD_ERR BOOL FALSE 1 = error in activate machine data job
43.2 DELDIST_ERR BOOL FALSE 1 = error in deleted remaining distance job
43.3 AVALREM_ERR BOOL FALSE 1 = error in cancel set actual value job
43.4 TRGL1WR_ERR BOOL FALSE 1 = error in write incremental dimension table
1 job
43.5 TRGL2WR_ERR BOOL FALSE 1 = error in write incremental dimension table
2 job
43.6 REFPT_ERR BOOL FALSE 1 = error in set reference point job
43.7 AVAL_ERR BOOL FALSE 1 = error in cancel set actual value job
44.0 FVAL_ERR BOOL FALSE Not used
44.1 ZOFF_ERR BOOL FALSE Not used
44.2 TRG252_254_ERR BOOL FALSE 1 = error in write incremental dimension for
incremental dimension number 254 job
44.3 TRG255_ERR BOOL FALSE 1 = error in write incremental dimension for
incremental dimension number 255 job
44.4 DELDIAG_ERR BOOL FALSE 1 = error in delete diagnostic buffer job