Setting parameters for blocks
3.5 Programming the Ident profile
Ident profile and Ident blocks, standard function for Ident systems
108 Function Manual, 10/2018, C79000-G8976-C387-04
Overview of the commands
Table 3- 90 Overview of the commands with which command repetition is possible
Command
Command code
Description
HEX
ASCII
PHYSICAL-READ 0x70 'p' Reads data from a transponder / optical reader sys-
tem by specifying the physical start address, the
length and the password.
PHYSICAL-WRITE 0x71 'q' Writes data to a transponder / optical reader system
by specifying the physical start address, the length
and the password.
READER-STATUS
0x74
't'
Reads out the status of the reader.
TAG-STATUS
0x73
's'
Reads out the status of a transponder.
INVENTORY 0x69 'i' Requests a list of all currently accessible transpond-
ers within the antenna range.
FORMAT
0x66
'f'
Initializes the transponder.
KILL-TAG 0x6A ‘j‘ RF61xR/RF68xR:
The transponder is permanently deactivated.
LOCK-TAG-BANK 0x79 ‘y‘ RF61xR/RF68xR:
Defines a password for transponder access.
Starting command repetition
You have the option of using command repetition with or without transfer of the command.
The various procedures are described below.
Sequence of the repeat command with simultaneous command transfer:
1. If applicable, enable presence mode (with RF61xR/RF68xR).
2. Start the command using the input parameter "EXECUTE" while "RPTCMD" is set at the
same time.
The command is processed and the result transferred to the Ident profile.
The Repeat command is activated on the reader.
3. The reader confirms activation with the output parameter "RPTACT" of the Ident profile.
The confirmation is made only after the first command has been executed.
The reader executes the command automatically as soon as a transponder is identified in
the antenna field.
If the reader does not support the Repeat command, "RPTACT" remains inactive. If
"EXECUTE" is nevertheless set, the error "0xE7FE0900" is output after a timeout of 10
seconds.
4. You can read out the individual results by repeatedly setting the "EXECUTE" input
parameter.