117
Address space of the transponder versions for RF600
Tags
Chip type
User
1)
[hex]
EPC
TID
(read only)
RESERVED
(passwords)
Special
Area /
length
Area / length
(max. and default)
Ac-
cess
Area / length
Area / length
KILL-PW
Lock
function
RF630L
(-2AB00,
-2AB01)
Impinj
Monza 2
- FF00-FF0B / 96 bits
FF00-FF0B / 96 bits
read/
write
FFC0-FFC3
4 bytes
FF80-FF87
8 bytes
Yes Yes
RF630L
(-2AB02)
Impinj
Monza
4QT
2)
00 - 3F
64 bytes
FF00-FF0F / 128 bits
FF00-FF0B / 96 bits
read/
write
FFC0-FFCB
12 bytes
FF80-FF87
8 bytes
Yes Yes
RF630L
(-2AB03)
NXP
G2XM
00 - 3F
64 bytes
FF00-FF1D / 240 bits
FF00-FF0B / 96 bits
read/
write
FFC0-FFC7
8 bytes
FF80-FF87
8 bytes
Yes Yes
RF640L
Alien
Higgs 3
00 -
0F/3F
3)
16/64
bytes
FF00-FF3C / 480 bits
FF00-FF0B / 96 bits
read/
write
FFC0-FFD8
24 bytes
FF80-FF87
8 bytes
Yes Yes
RF642L
NXP /
UCODE
7xm-2k
00 - FF
256
bytes
FF00-FF38 / 448 bits
FF00-FF0B / 96 bits
read/
write
FFC0-FFCB
12 bytes
FF80-FF87
8 bytes
Yes Yes
RF680L
NXP
G2XM
00 - 3F
64 bytes
FF00-FF1D / 240 bits
FF00-FF0B / 96 bits
read/
write
FFC0-FFC7
8 bytes
FF80-FF87
8 bytes
Yes Yes
RF690L
Alien
Higgs 3
00 -
0F/3F
3)
16/64
bytes
FF00-FF3C / 480 bits
FF00-FF0B / 96 bits
read/
write
FFC0-FFD8
24 bytes
FF80-FF87
8 bytes
Yes Yes
RF610T
NXP
G2XM
00 - 3F
64 bytes
FF00-FF1D / 240 bits
FF00-FF0B / 96 bits
read/
write
FFC0-FFC7
8 bytes
FF80-FF87
8 bytes
LOCKED Yes
RF620T
Impinj
Monza
4QT
2)
00 - 3F
64 bytes
FF00-FF0F / 128 bits
FF00-FF0B / 96 bits
read/
write
FFC0-FFCB
12 bytes
FF80-FF87
8 bytes
LOCKED Yes
RF625T
Impinj
Monza
4QT
2)
00 - 3F
64 bytes
FF00-FF0F / 128 bits
FF00-FF0B / 96 bits
read/
write
FFC0-FFCB
12 bytes
FF80-FF87
8 bytes
LOCKED Yes
RF630T
NXP
G2XM
00 - 3F
64 bytes
FF00-FF1D / 240 bits
FF00-FF0B / 96 bits
read/
write
FFC0-FFC7
8 bytes
FF80-FF87
8 bytes
LOCKED Yes
RF640T
NXP
G2XM
00 - 3F
64 bytes
FF00-FF1D / 240 bits
FF00-FF0B / 96 bits
read/
write
FFC0-FFC7
8 bytes
FF80-FF87
8 bytes
LOCKED Yes
RF680T
NXP
G2XM
00 - 3F
64 bytes
FF00-FF1D / 240 bits
FF00-FF0B / 96 bits
read/
write
FFC0-FFC7
8 bytes
FF80-FF87
8 bytes
LOCKED Yes
RF682T
NXP
UCode
DNA
00 - 17F
384
bytes
FF00-FF38 / 448 bits
FF00-FF0B / 96 bits
read/
write
FFC0-FFCB
12 bytes
FF80-FF87
8 bytes
LOCKED Yes
1)
The user area also applies to the readers RF61xR/RF650R/RF68xR in memory bank 3.
2)
Uses User Memory Indicator (UMI).