Error messages
4.3 Errors from the communications module/reader
Ident profile and Ident blocks, standard function for Ident systems
Function Manual, 10/2018, C79000-G8976-C387-04
123
0xE1FE0400 Only during initialization: Transponder is unable to execute the initialization command
• Transponder is defective
0xE1FE0600 Error in transponder memory
The transponder has never been written to or has lost the contents of its memory due to battery failure.
• Replace transponder (if battery bit is set)
• Re-initialize transponder
0xE1FE0700 Password error
RF620R/RF630R: Incorrect password
The transponder in the antenna field does not have the expected UID or has no UID.
The transponder is read/write-protected.
The transponder is not responding.
The transponder password is incorrect. Access is denied.
The verification of the written transponder data has failed.
General transponder error
The transponder has too little power to execute the command.