Error messages
4.3 Errors from the communications module/reader
Ident profile and Ident blocks, standard function for Ident systems
Function Manual, 10/2018, C79000-G8976-C387-04
127
Error mes-
sage
(hex)
Description
0xE5FE0800 Previous command is active or buffer overflow
A new command was sent to the reader or communications module although the last command was still
active.
Active command can only be terminated with an "INIT"
Before a new command can be started, "DONE bit = 1" must be set (exception "INIT")
Two Ident profile calls were assigned the same "HW_ID", "CM_CHANNEL" and "LADDR" parameter
settings
Two Ident profile calls are using the same pointer
Start "INIT" after correcting the error
When working with command repetition (e.g., fixed code transponder), no data is being fetched from
the transponder. The data buffer on the reader/communications module has overflowed. Transponder
data has been lost.
0xE5FE0900 The reader or communications module executes a hardware reset ("INIT_ACTIVE" set to "1"). "INIT" is
expected by the Ident profile (bit 15 in the cyclic control word).
0xE5FE0A00 The "CMD" command code and the relevant acknowledgement do not match. This can be a software error
or synchronization error that cannot occur in normal operation.
0xE5FE0B00
Incorrect sequence of acknowledgement frames (TDB / DBN)
0xE5FE0C00 Synchronization error (incorrect increment of AC_H / AC_L and CC_H / CC_L in the cyclic control word).
"INIT" had to be executed
0xE5FE8100 Communications error between reader and communications module
Access denied
0xE5FE8200 Communications error between reader and communications module
Resource is occupied
0xE5FE8300 Communications error between reader and communications module
Functional error of the serial interface
0xE5FE8400 Communications error between reader and communications module
Other faults/errors
0xE6FE0100 Unknown command
Ident profile is sending an uninterpretable command to the communications module.
The "AdvancedCmd" block was supplied with an incorrect "CMD".
The "CMD" input of the "AdvancedCmd" block was overwritten by the user.
The transponder has signaled an address error.
0xE6FE0200
Invalid command index CI