A.2 Cyclic data
Ident profile and Ident blocks, standard function for Ident systems
140 Function Manual, 10/2018, C79000-G8976-C387-04
Command termination with "SRESET"
The "SRESET" command cancels execution of the command currently being processed. It is
transferred from block (controller) to block (reader/optical reader) by means of cyclic
communication (control and status word). Handshake is performed via "SRESET" and
"Soft_Reset_Active". After the "SRESET" block parameter is set, the block assigns the
control to the control bit "Soft_Reset". During this time, the execution of "RD_REC" and
"WR_REC" cannot be interrupted. This means that the assignment process can only take
place after execution of "RD_REC" or "WR_REC" is complete.
A prerequisite for the "SRESET" command is that the command and acknowledgment
counter are initialized within the block (reader/optical reader) and the status word. "SRESET"
does not have an effect on the sequence number (SN within the frame header).
a CC_H/CC_L = 1, AC_H/AC_L = 0
Defined reset
Figure A-3 Time sequence of "SRESET"