Setting par
ameter
s for b
lock
s
3.4
Progra
mming
Ident b
locks
Ident profile and Ident blocks,
standard function for Ident systems
40
Functi
on Manual
,
10/2018
,
C7900
0
-
G8976
-
C387
-
04
Table
3-
17
ATTRIBUTE "0x81"
Name
Type
Comment
NUM
MDS
WORD
Number of MDS
TAG_DATA
ARRAY[1..n] of
IID
IN
I
81
TAG_DATA[1]
IID_IN_1_81
reserved
BYTE
ID_LEN
BYTE
EPC length
EPC_ID
ARRAY[1..62]of
BYTE
EPC
-
ID
tagPC
WORD
RSSI
BYTE
RSSI value
MaxRSSI
BYTE
highest RSSI value
MinRSSI
BYTE
lowest RSSI value
channel
BYTE
channel; 1..15_ESTI; 1..53:FCC
antenna
BYTE
antenna; bit coded;
Bit 0 = antenna 1; Bit 1 = antenna 2;
Bit 2 = antenna 3; Bit 3 = antenna 4
polarization
BYTE
polarizatuin of antenna;
0=undefined; 1=circular; 2=vertical linear;
3=horizontal
time
Time_OF_Day
S7 timestamp
power
BYTE
power in dBm
filterDataAvailable
BYTE
0=false; 1=true
Inventoried
WORD
1)
TAG_DATA[2]
IID_IN_1_81
...
...
TAG_DATA[n]
IID_IN_1_81
1)
Indicates h
ow often th
e transponder w
as ident
ified via t
he air interf
ace before i
t changed t
o the "Ob
served" st
atus.
39
41
Table of Contents
Main Page
Default Chapter
3
Table of Contents
3
1 Introduction
5
2 Description
7
Area of Application and Features
7
Building Block Structure
10
Differentiation from Other Program Blocks
11
3 Setting Parameters for Blocks
13
Overview of the Ident Library
13
Setting the "IID_HW_CONNECT" Data Type
17
General Structure of the Function Blocks
20
Programming Ident Blocks
24
Basic Blocks
24
Read
24
Read_Mv
25
Reset_Reader
26
Set_Mv_Program
27
Write
27
Extended Blocks
29
Config_Upload/-_Download
29
Inventory
31
Read_Epc_Mem
41
Read_Tid
42
Read_Uid
43
Set_Ant
43
Set_Param
45
Write_Epc_Id
48
Write_Epc_Mem
49
Advancedcmd
50
Reset Blocks
51
Reset_Moby_D
51
Reset_Moby_U
52
Reset_Mv
53
Reset_Rf200
54
Reset_Rf300
55
Reset_Rf600
56
Reset_Univ
57
Status Blocks
58
Reader_Status
58
Tag_Status
64
Programming the Ident Profile
68
Changing to Ident Blocks / Profile
68
Structure of the Ident Profile
71
Data Structure of the Ident Profile
75
Commands of the Ident Profile
77
Command Structure
79
Commands
81
Expanded Commands for Optical Reader Systems (MV400/MV500)
99
Effect of the Commands
103
Editing Commands
104
Parameter Assignment for Starting up and Restarting
105
Chaining
105
Command Repetition
107
Transponder Addressing
113
4 Error Messages
121
Structure of the "STATUS" Output Parameter
121
4.2 STEP 7 - Error Messages
122
Errors from the Communications Module/Reader
122
Errors from the Optical Reader
130
Errors from the Bus/Backplane Bus
132
Warnings
132
Appendix
133
Internal Status Parameter
133
A.1 Internal Status Parameter
133
Cyclic Data
135
Cyclic Control Word
135
A.2 Cyclic Data
135
Cyclic Status Word
136
Using the Acknowledgment and Command Counter
137
Service & Support
141
A.3 Service & Support
141
Other manuals for Siemens SIMATIC Ident
Operating Manual
80 pages
System Manual
362 pages
Installation Manual
26 pages
Operating Instructions
58 pages
Compact Operating Instructions
18 pages
Related product manuals
Siemens SIMATIC RF650R
344 pages
Siemens SIRIUS 3R
2 pages
Siemens SIRIUS 3RP15 series
4 pages
Siemens Acuson S2000
518 pages
Siemens Acuson S1000
518 pages
Siemens Acuson S3000
518 pages
Siemens SIMATIC Ident RF200
46 pages
Siemens 3AH
33 pages
Siemens 8DA10
48 pages
Siemens 8DA12
48 pages
Siemens 8DA series
48 pages
Siemens 7SG11 Argus
22 pages