Setting parameters for blocks
3.5 Programming the Ident profile
Ident profile and Ident blocks, standard function for Ident systems
74 Function Manual, 10/2018, C79000-G8976-C387-04
Table 3- 53 Output parameter
TRUE = Command was executed free of errors.
ERROR BOOL FALSE TRUE = Error was detected.
The error is output in the "STATUS" parameter. The bit is
reset automatically when a new command is started.
STATUS DWORD FALSE Warning and error
If "ERROR = TRUE" or "WARNING = TRUE", the error or
warning information is contained in the "STATUS" parame-
ter. For more information, refer to the section "
Error mes-
WARNING BOOL FALSE TRUE = Warning was detected.
The warning is output in the "STATUS" parameter. If the
"ERROR" parameter is not set at the same time, the data
was correctly processed. The bit is reset automatically when
a new command is started.
BUSY BOOL FALSE TRUE = the block is executing a command.
Other commands except for "INIT" and "SRESET" cannot
RPTACT BOOL FALSE TRUE = "RPTCMD" is active
The acknowledgment bit shows that the "Repeat mode" of
ERR_IREQ BOOL FALSE TRUE = An error has occurred on the communications
module or reader (e.g. on start-up of the reader, connection
termination or with RF61xR, RF68xR on antenna errors or
TPC BOOL FALSE Transponder Presence Changed (only when Pres-
ence_Mode is active)
TRUE = A new transponder enters the antenna field of the
reader or a transponder has left the antenna field.
The parameter is set to "FALSE" after the successful execu-
tion of the next "INVENTORY" (0x80, 0x81, 0x87) or "INIT"
TP BOOL FALSE Transponder Presence
TRUE = There is a transponder in the antenna field of the