Setting parameters for blocks
3.5 Programming the Ident profile
Ident profile and Ident blocks, standard function for Ident systems
78 Function Manual, 10/2018, C79000-G8976-C387-04
Command
Command code
Parameters used
Description
HEX
ASCII
WRITE-ID 0x67 ‘g‘ OFFSETBUFFER,
EPCID_UID, LEN_ID,
NEW-LEN_ID, PSWD
RF61xR/RF68xR:
Writes a new EPC-ID to the transponder.
KILL-TAG 0x6A ‘j‘ EPCID_UID, LEN_ID,
PSWD
RF61xR/RF68xR:
The transponder is permanently deactivated.
LOCK-TAG-BANK 0x79 ‘y‘ EPCID_UID, LEN_ID,
PSWD, ACTION, MASK
RF61xR/RF68xR:
The corresponding memory area of the tran-
sponder is blocked as specified.
EDIT-BLACKLIST 0x7A ‘z‘ EPCID_UID, LEN_ID,
MODE
RF61xR/RF68xR:
The black list is processed. The current tran-
sponder can be added, all identified transponders
added, individual transponders deleted or all tran-
sponders deleted.
GET-BLACKLIST 0x6C ‘l‘ OFFSETBUFFER RF61xR/RF68xR:
The entire TagIDs are read out from the black list.
READ-CONFIG 0x61 'a' -- Reads out the parameters from the communica-
tions module/reader.
WRITE-CONFIG 0x78 'x' LEN_DATA, CONFIG Sends new parameters to the communications
module/reader.

Table of Contents

Other manuals for Siemens SIMATIC Ident

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC Ident and is the answer not in the manual?

Siemens SIMATIC Ident Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC Ident
CategoryOther
LanguageEnglish

Related product manuals