EasyManua.ls Logo

Siemens SIMATIC Ident - Page 84

Siemens SIMATIC Ident
142 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Setting parameters for blocks
3.5 Programming the Ident profile
Ident profile and Ident blocks, standard function for Ident systems
84 Function Manual, 10/2018, C79000-G8976-C387-04
Table 3- 60 INVENTORY
Parameter
Value / description
CMD
0x69
OFFSETBUFFER Offset in the "RXREF" receive buffer
ATTRIBUTES Identifier of the status modes / possible entries:
RF61xR/RF68xR:
0x80 inventory with brief transponder information
0x81 ≙ inventory with a lot of transponder information
0x86 ≙ Presence mode on
0x87 ≙ Presence mode off
RF620R/RF630R:
0x82 ≙ read out the next data record
0x83 ≙ read handle ID when MOBY_mode ≙ 6 and EPC-ID when
MOBY_mode ≙ 7
0x85 ≙ read out handle IDs and EPC-IDs sorted in descending
order according to the mean RSSI value
0x91 ≙ read out handle IDs sorted in descending order according
to the maximum RSSI value
0x92 ≙ read out handle IDs sorted in descending order according
to read frequency
0xA0 ≙ read out first entries from Black List
0xA1 ≙ read out further entries from Black List
RF300/MOBY U:
0x00 ≙ list of all tags with UID
INVENTORY_DURATION Only for 0x80 and 0x81:
Duration
Period of time or number of inventories or number of "Observed"
events
Example:
0x00 ≙ no inventory
0x01 ≙ one inventory