Setting parameters for blocks
3.5 Programming the Ident profile
Ident profile and Ident blocks, standard function for Ident systems
Function Manual, 10/2018, C79000-G8976-C387-04
83
Table 3- 58 READER-STATUS
Parameter
Value / description
CMD
0x74
OFFSETBUFFER Offset in the "RXREF" receive buffer
ATTRIBUTES Identifier of the status modes / possible entries:
RF200: 0x81
RF300: 0x81, 0x86
RF620R, RF630R: 0x87, 0x88, 0xA0, 0xA1
RF61xR, RF68xR: 0x89
RF185C, RF186C, RF188C: 0xA2
MOBY U: 0x81, 0x84, 0x85
MOBY D: 0x81
RXREF Received status data
You will find the data structure of the status modes in the section
"Reader_Status (Page 58)".
Table 3- 59 TAG-STATUS
Parameter
Value / description
CMD
0x73
OFFSETBUFFER
Offset in the "RXREF" receive buffer
ATTRIBUTES Identifier of the status modes / possible entries:
RF200: 0x83
RF300 (RF300T): 0x04, 0x82
RF300 (ISO): 0x83
RF300 Gen2: 0x83
RF600 (R620R, RF630R): 0x84, 0x85
MOBY D: 0x83
1)
MOBY U: 80
EPCID_UID Buffer for up to 62 bytes EPC-ID, 8 bytes UID or 4 bytes handle ID.
2 - 62-byte EPC-ID is entered at the start of the buffer (length is
set by "LEN_ID")
8-byte UID is entered at the start of the buffer ("LEN_ID = 8")
4-byte handle ID must be entered in the array element [5]-[8]
("LEN_ID = 8")
Default value: 0x00 ≙ unspecified single tag access
LEN_ID
Length of the EPC-ID/UID
RXREF Received status data
You will find the data structure of the status modes in the section
"Tag_Status (Page 64)".
1)
SLG D10S only