Configuring with Web Based Management
5.5 "System" menu
SCALANCE W760/W720 to IEEE 802.11n Web Based Management
136 Configuration Manual, 11/2014, C79000-G8976-C350-03
Upper IP Address
Enter the IPv4 address that specifies the end of the dynamic IPv4 address band. The
IPv4 address must be within the network address range you configured for "Subnet".
Lease Time [sec]
Specify for how many seconds the assigned IPv4 address remains valid. Once this period
has elapsed, the device must either request a new IPv4 address or extend the lease time
of the existing IPv4 address.
5.5.10.3
DHCP Options
Note
This tab is available only on the client SCALANCE W722
-1 RJ-45.
On this page you specify which DHCP options the DHCP server supports. The various
DHCP options are defined in RFC 2132.