SCALANCE W760/W720 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C350-03
235
Upkeep and maintenance
6
6.1
Firmware update - via WBM
Requirement
The device has an IP address.
The "admin" user is logged on.
Firmware update via HTTP
1. Click "System > Load&Save" in the navigation area. Click the "HTTP" tab.
2. Click the "Load" button in the "Firmware" table row.
3. Go to the storage location of the firmware file.
4. Click the "Open" button in the dialog. The file is uploaded.
Firmware update - via TFTP
1. Click "System > Load&Save" in the navigation area. Click the "TFTP" tab.
2. Enter the IP address of the TFTP server in the "TFTP Server IP Address" input box.
3. Enter the port of the TFTP server in the "TFTP Server Port" input box
4. Click the "Load file" button in the "Firmware" table row.
5. Go to the storage location of the firmware file.
6. Click the "Open" button in the dialog. The file is uploaded.
Result
The firmware is has been transferred completely to the device and under ""Information >
Versions" there is also the entry "FirmwareRunning". FirmwareRunningshows the version of
the current firmware. Firmware shows the firmware version stored after loading the firmware.
To activate this firmware, restart the device with "System > Restart".

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE W721-1 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE W721-1 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE W721-1
CategoryControl Unit
LanguageEnglish

Related product manuals