Configuring with Web Based Management
5.6 "Interfaces" menu
SCALANCE W760/W720 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C350-03
175
HW Retries
Specify the number of hardware retries. The hardware repetition is performed by the
WLAN chip itself when it tries to repeat an unacknowledged packet immediately.
If all hardware repetitions were unsuccessful, the packet is deleted.
Force roaming on link down (Only in access point mode)
If the wired Ethernet interface is no longer available (cable break, connector removed), a
client connected over the wireless network is not aware of this. The access point can
force the logged-on clients to roam by deactivating its WLAN interface. The client then
attempts to log on at a different access point. You enable this feature by selecting the
"Force Roaming on link down" check box.
Procedure
1. Enter the values to be set in the input boxes as follows.
2. Click the "Set Values" button.
5.6.2.3
Antennas
Overview
Overview of IWLAN antennas:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE W721-1 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE W721-1 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE W721-1
CategoryControl Unit
LanguageEnglish

Related product manuals