Configuring with Web Based Management
5.5 "System" menu
SCALANCE W760/W720 to IEEE 802.11n Web Based Management
160 Configuration Manual, 11/2014, C79000-G8976-C350-03
5.5.13
Auto Logout
Setting the automatic logout
On this page, set the times after which there is an automatic logout from WBM or the CLI
following user in activity.
If you have been logged out automatically, you will need to log in again.
Procedure
1. Enter a value of 60-3600 seconds in the "Web Based Management (s)" input box. If you
enter the value 0, the automatic logout is disabled.
2. Enter a value of 60-600 seconds in the "CLI (TELNET, SSH) (s)" input box. If you enter
the value 0, the automatic logout is disabled.
3. Click the "Set Values" button.
5.5.14
Syslog Client
System event agent
Syslog according to RFC 3164 is used for transferring short, unencrypted text messages
over UDP in the IP network. This requires a Syslog server.
Requirements for sending log entries:
The Syslog function is enabled on the device.
The Syslog function is enabled for the relevant event.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE W721-1 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE W721-1 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE W721-1
CategoryControl Unit
LanguageEnglish

Related product manuals