Configuring with Web Based Management
5.3 "Wizard" menu
SCALANCE W760/W720 to IEEE 802.11n Web Based Management
52 Configuration Manual, 11/2014, C79000-G8976-C350-03
Description
Table 1 contains the following columns:
Radio
Shows the available WLAN interface.
MAC Mode
Specify how the MAC address is assigned to the client. The following are possible:
Automatic
The client automatically adopts the source MAC address of the first frame that it
receives over the Ethernet interface.
Manual
If you select "Manual", enter the MAC address in the "MAC Address" column.
Own
The client uses the MAC address of the Ethernet interface for the WLAN interface.
Layer 2 Tunnel
The client uses the MAC address of the Ethernet interface for the WLAN interface.
The network is also informed of the MAC addresses connected to the Ethernet
interface of the client. Up to 4 MAC addresses can be used.