Configuring with Web Based Management
5.4 "Information" menu
SCALANCE W760/W720 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C350-03
75
Bridge Status
Shows the status of the bridge, e.g. whether or not the device is the root bridge.
Regional Root Priority
(only available with MSTP)
For a description, see Bridge Priority / Root Priority
Regional Root Address
(only available with MSTP)
Shows the MAC address of the device.
Regional Root Cost
(only available with MSTP)
Shows the path costs from the regional root bridge to the root bridge.
The table contains the following boxes:
Port
Shows the port via which the device communicates.
Role
shows the status of the port. The following values are possible:
Disabled
The port was removed manually from the spanning tree and will no longer be taken
into account by the spanning tree.
Designated
The ports leading away from the root bridge.
Alternate
The port with an alternative route to a network segment
Backup
If a switch has several ports to the same network segment, the "poorer" Port becomes
the backup port.
Root
The port that provides the best route to the root bridge.
Master
This port points to a root bridge located outside the MST region.
State
Displays the current status of the port. The values are only displayed. The parameter
depends on the configured protocol. The following statuses are possible:
Discarding
The port receives BPDU frames. Other incoming or outgoing frames are discarded.
Listening
The port receives and sends BPDU frames. The port is involved in the spanning tree
algorithm. Other outgoing and incoming frames are discarded.
Learning
The port actively learns the topology; in other words, the node addresses. Other
outgoing and incoming frames are discarded.
Forwarding
Following the reconfiguration time, the port is active in the network. The port receives
and sends data frames.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE W721-1 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE W721-1 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE W721-1
CategoryControl Unit
LanguageEnglish

Related product manuals