Configuring with Web Based Management
6.4 "Information" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 08/2018, C79000-G8976-C267-13
147
Description of the displayed values
This table contains the following columns:
Role
Shows the name of the role.
Function Right
Shows the function right of the role:
1
Users with this role can read device parameters but cannot change them.
15
Users with this role can both read and change device parameters.
0
This is a role that the device assigns internally when a user could not be
authenticated. The user is denied access to the device.
Description
Shows a description of the role.
6.4.13.4
Groups
Note
The values displayed depend on the role of the logged
-on user.
This page shows which group is linked to which role. The group is defined on a RADIUS
server. The roll is defined locally on the device.