Configuring with Web Based Management
6.5 "System" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 08/2018, C79000-G8976-C267-13
213
●
The device sends an e-mail. This is only possible if the SMTP server is set up and the
"SMTP client" function is enabled.
●
The device sends an SNMP trap. This is only possible if "SNMPv1 Traps" is enabled in
"System > Configuration".
●
The device writes an entry in the event log table.
●
The device writes an entry to the system log server. This is only possible if the system log
server is set up and the "Syslog client" function is enabled.
●
The device triggers an error. The error LED lights up.
Follow the steps below to change entries:
1. Select the check box in the row of the required event. Select the event in the column
under the following actions:
– E-mail
– Trap
– Log table
– Syslog
– Error
2. Click the "Set Values" button.
On this page, you configure the severity for the sending of system event notifications.