Configuring with Web Based Management
6.5 "System" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 08/2018, C79000-G8976-C267-13
181
DNS Client
Enable or disable the DNS client. You can configure other settings in "System > DNS".
SMTP Client
Enable or disable the SMTP client. You can configure other settings in "System > SMTP
Client".
Syslog Client
Enable or disable the Syslog client. You can configure other settings in "System > Syslog
Client".
DCP Server
Specify whether or not the device can be accessed with DCP (Discovery and
Configuration Protocol):
"-" (disabled)
DCP is disabled. Device parameters can neither be read nor modified.
Read/Write
With DCP, device parameters can be both read and modified.
Read Only
With DCP, device parameters can be read but cannot be modified.
Time
Select the setting from the drop-down list. The following settings are possible:
Manual
The system time is set manually. You can configure other settings in "System >
System Time > Manual Setting".
SIMATIC Time
The system time is set using a SIMATIC time transmitter. You can configure other
settings in "System > System Time > SIMATIC Time Client".
SNTP Client
The system time is set via an SNTP server. You can configure other settings in
"System > System Time > SNTP Client".
NTP Client
The system time is set via an NTP server. You can configure other settings in "System
> System Time > NTP Client".
SNMP
Select the protocol from the drop-down list. The following settings are possible:
"-" (SNMP disabled)
Access to device parameters via SNMP is not possible.
SNMPv1/v2c/v3
Access to device parameters is possible with SNMP versions 1, 2c or 3. You can
configure other settings in "System > SNMP > General".
SNMPv3
Access to device parameters is possible only with SNMP version 3. You can configure
other settings in "System > SNMP > General".

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE W780 Series and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE W780 Series Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE W780 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals