Configuring with Web Based Management
6.5 "System" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
222 Configuration Manual, 08/2018, C79000-G8976-C267-13
Description
The page contains the following boxes:
Pool ID
Select the required IPv4 address band.
Option Code
Enter the number of the required DHCP option. A maximum of 20 DHCP options are
possible.
The various DHCP options are defined in RFC 2132. The DHCP options 1, 3, 6, 12, 66
and 67 are created automatically when the IPv4 address band is created. With the
exception of option 1, the options can be deleted.
With the DHCP option 3, the internal IPv4 address of the device is automatically set as a
DHCP parameter
Note
DHCP options not supported
The DHCP options 50
- 60 and 255 are not supported.
The table has the following columns:
Select
Select the check box in the row to be deleted.
Pool ID
Shows the number of the IPv4 address band.
Option Code
Shows the number of the DHCP option.