Configuring with Web Based Management
6.6 "Interfaces" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
314 Configuration Manual, 08/2018, C79000-G8976-C267-13
CSV file
The CSV file contains information on the configuration of the SCALANCE W700 device and
detailed information on all individual measurements and is divided into two areas. The first
area contains the configured settings:
System Name
The system name of the client
Device IP
The IP address of the client
Device MAC
The MAC address of the client
Recording Interval
The interval between acquisition of two measured values
Max TX Power
Maximum transmit power of the device
Begin Recording
Start of the recording
End Recording
End of the recording
Recorded Samples
The total number of measurements
Max. TX Rate
The maximum data rate of the sent data packets.
Max. RX Rate
The maximum data rate of the received data packets.
Rx Antenna x type
The setting of the external antennas
The second area is a table. The table contains the following for each measured value:
Sample
The current number of the measurement on the client (CL) / on the access point (AP)
Timestamp
The time stamp
BSSID
The BSSID (Basic Service Set Identification) of the access point
CL / AP RX-Signal [%]
The effective user data signal of the client (CL) / access point (AP) in %

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE W780 Series and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE W780 Series Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE W780 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals