Configuring with Web Based Management
6.7 "Layer 2" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 08/2018, C79000-G8976-C267-13
345
MSTP Status
Click the check box to enable or disable this option.
Priority
Enter the priority of the port. The priority is only evaluated when the path costs are the
same.
The value must be divisible by 16. If the value that cannot be divided by 16, the value is
automatically adapted.
Range of values: 0 - 240.
The default is 128.
Cost Calc.
Enter the path cost calculation in the input box. If you enter the value "0" here, the
automatically calculated value is displayed in the next box "Path Costs".
Path Cost
The path costs from this port to the root bridge. The path with the lowest value is selected
as the path. If several ports of a device have the same value, the port with the lowest port
number will be selected.
If the "Cost Calc." box has the value "0", the automatically calculated value is shown.
Otherwise, the value of the "Cost Calc." box is displayed.
The calculation of the path costs is largely based on the transmission speed. The higher
the achievable transmission rate, the lower the value for the path costs will be.
Typical values for rapid spanning tree are as follows:
1000 Mbps = 20,000
100 Mbps = 200,000
10 Mbps = 2,000,000
The values can, however, also be set individually.
Status
Displays the current status of the port. The values are only displayed and cannot be
configured. The following is possible for status:
Discarding
The port exchanges MSTP information but is not involved in the data traffic.
Blocked
In the blocking mode, BPDU frames are received.
Forwarding
The port receives and sends data frames.
Fwd. Trans.
Specifies the number of status changes Discarding - Forwarding or Forwarding -
Discarding.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE W780 Series and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE W780 Series Specifications

General IconGeneral
IP RatingIP30
Product TypeWireless Access Point
Frequency Bands2.4 GHz, 5 GHz
Wireless StandardIEEE 802.11a/b/g/n/ac
Data RateUp to 1.3 Gbps
Operating Temperature-20°C to +60°C
Power Supply24 V DC
Mounting TypeDIN rail, wall
SecurityFirewall
ManagementWeb-based, SNMP, CLI
Weight0.6 kg

Related product manuals