Configuring with Web Based Management
6.9 "Security" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 08/2018, C79000-G8976-C267-13
379
Description
The page contains the following boxes:
Reauthentication Mode
Specify who sets the time after which the clients are forced to reauthenticate.
- (disabled)
Reauthentication mode is disabled.
Server
Enables time management on the server.
Local
Enables local time management. In "Reauthentication Interval", specify the time of
validity.
Reauthentication Interval [s]
If time management is local, enter the period of validity of the authentication in seconds.
The minimum time is 1 minute (enter 60), the maximum time is 12 hours (enter 43200).
The default is one hour (3,600 seconds).
The table has the following columns:
Server IP Address
Here, enter the IP address or the FQDN name of the RADIUS server.
Server Port
Here, enter the input port on the RADIUS server.
Shared Secret
Enter the password of the RADIUS server.
For the password, ASCII code 0x20 to 0x7e is used.
Shared Secret Conf
Confirm the password.
Max. Retransmissions
Enter the maximum number of connection attempts.
Primary Server
Specify whether or not this server is the primary server.
Yes: Primary server
No: Backup server.
State
With this check box, you can enable or disable the RADIUS server
Procedure
Entering a new server