Security recommendations
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 03/2018, C79000-G8976-C386-06
13
List of available protocols
All available protocols and their ports that can be used with SIMATIC RF650R, RF680R and
RF685R are listed below.
Table 2- 1 List of available protocols
Protocol
Port number
Default port
status
Port configura-
ble
Authentication
Encryption
SSH
(OEM only)
TCP/22 Open -- Yes Yes
XML service TCP/10001 Open -- No No
DHCP
UDP/68
Closed
No
No
PROFINET UDP/34964
UDP/49152-65535
Open No No
HTTP
TCP/80
Open
--
No
No
HTTPS
TCP/443
Closed
Yes
Yes
NTP
UDP/123
Closed
No
No
SNMP
UDP/161
Closed
No
No
OPC UA TCP/4840 Open Yes (simple,
when config-
ured)
No
Ethernet/IP TCP/44818
UDP/44818
UDP/2222
Open No No