Programming via XML interface
10.3 XML commands
SIMATIC RF650R/RF680R/RF685R
204 Configuration Manual, 03/2018, C79000-G8976-C386-06
The error codes for negative replies ("resultCode" ≠ 0) are described in the section "Negative
XML replies (Page 263)".
Parameter
Parameter
Type
Values
Description
value_id Decimal value
0...9
0...4294967295 Unique command identifier
value_logType Fixed values Diagnosis Optional
Type of diagnostics file
Diagnostics: Log file
value_logData CDATA -- Data logged by the reader
The parameter must be embedded in a
CDATA segment.
10.3.2.6
resetLogfile
This command deletes all the entries in the log.
Command
<frame>
<cmd>
<id> value_id </id>
<resetLogfile/>
</cmd>
</frame>
Reply
<frame>
<reply>
<id> value_id </id>
<resultCode> 0 </resultCode>
<resetLogfile/>
</reply>
</frame>