Programming via XML interface
10.3 XML commands
SIMATIC RF650R/RF680R/RF685R
196 Configuration Manual, 03/2018, C79000-G8976-C386-06
10.3.1.4
setIPConfig
This command is available as of API V2.2.
The IP address of the reader is changed with this command. If the transferred parameters do
not contain any inconsistencies, the reader will terminate the connection. This happens as
well if the parameters are identical to the previous settings. A response frame is sent in reply
to this command only if there is an error.
Command
<frame>
<cmd>
<id> value_id </id>
<setIPConfig>
<iPAddress> value_iPAddress </iPAddress> // opt
<subNetMask> value_subNetMask </subNetMask> // opt
<gateway> value_gateway </gateway> // opt
<dHCPEnable> value_dHCPEnable </dHCPEnable> // opt
</setIPConfig>
</cmd>
</frame>
// opt → Optional: Line can be omitted.
Reply
<frame>
<reply>
<id> value_id </id>
<resultCode> 0 </resultCode>
<setIPConfig/>
</reply>
</frame>
The error codes for negative replies ("resultCode" ≠ 0) are described in the section "Negative
XML replies (Page 263)".