Appendix
A.2 Application examples of the algorithms
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 03/2018, C79000-G8976-C386-06
321
Note: The algorithm "Read/Write Power Ramp" is based on the algorithm "Inventory Power
Ramp". This means that the dB values of the "Read/Write Power Ramp" are added to the
existing values increased by the "Inventory Power Ramp".
A.2.2
Inventories limited by time
Description
In this example inventories will be taken as soon as an event occurs - e.g. when a forklift
truck passes and interrupts a light barrier (input 1). The aim is that all transponders on the
palette of the forklift truck are reported as ""reliably identified" if they are scanned often
enough.
In this example there are different procedures depending on the user type (S7/Rockwell user
or XML/OPC user).
In addition, there are two different examples (A and B) in which a distinction is made as to
when the inventories are ended again.
Example A:
The inventories are taken over a specified time of 10 seconds.
Example B:
The inventories are taken until the light barrier is no longer interrupted.
Algorithms used
Smoothing
Requirement
The read points are mounted, equipped and aligned.
Parameter assignment - S7 / Rockwell user
Follow the steps below to activate the "Smoothing" algorithm:
1. In the menu item "Settings - Read points" in the "Algorithms" area activate the
"Smoothing" algorithm and specify the values as follows:
Observed Count: Here enter a value that guarantees reliable identification of the
transponders and at the same time ensures that transponders identified by sporadic
overshoots are sorted out. With the menu item "Diagnostics - Tag monitor" you can
determine which value is ideal here for your application.
Lost Count: Enter the maximum value "65535" to ensure that all transponders are
identified during the specified period (status: observed). With this value you ensure
that the identified transponders are reported as "identified" over the entire time of the
inventory, even if the transponders have already left the antenna field.

Table of Contents

Other manuals for Siemens SIMATIC RF650R

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC RF650R and is the answer not in the manual?

Siemens SIMATIC RF650R Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC RF650R
CategoryOther
LanguageEnglish

Related product manuals