Programming via SIMATIC controller
8.6 Programming the Ident profile
SIMATIC RF650R/RF680R/RF685R
146 Configuration Manual, 03/2018, C79000-G8976-C386-06
Overview of the commands
Table 8- 34 Overview of the commands with which chaining is possible
Command
Command code
Description
HEX
ASCII
PHYSICAL-READ 70 'p' Reads data from a transponder by specifying the
physical start address of the memory bank (UHF), the
length and the password.
PHYSICAL-WRITE 71 'q' Writes data to a transponder by specifying the physi-
cal start address of the memory bank (UHF), the
length and the password.
INVENTORY
1)
69 'i' Requests a list of all currently accessible transpond-
ers within the antenna range.
DEV-STATUS 74 't' Reads out the status of a communications module.
This command must not be the last command within
the chain.
WRITE-ID 67 ‘g‘ RF680R/RF685R:
Writes a new EPC-ID to the transponder.
KILL-TAG 6A ‘j‘ RF680R/RF685R:
The transponder is permanently deactivated.
LOCK-TAG-BANK 79 ‘y‘ RF680R/RF685R:
Defines a password for transponder access.
1)
Note that chaining of commands must not start with the "INVENTORY" command, because the
"INVENTORY" command is executed directly.

Table of Contents

Other manuals for Siemens SIMATIC RF650R

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC RF650R and is the answer not in the manual?

Siemens SIMATIC RF650R Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC RF650R
CategoryOther
LanguageEnglish

Related product manuals