EasyManua.ls Logo

Siemens SIMATIC RF650R

Siemens SIMATIC RF650R
344 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programming via XML interface
10.3 XML commands
SIMATIC RF650R/RF680R/RF685R
206 Configuration Manual, 03/2018, C79000-G8976-C386-06
Parameter
Parameter
Type
Values
Description
value_id Decimal value
0...9
0...4294967295 Unique command identifier
value_name Alphanumeric text See following
table
Name of the supported parameter
value_value Alphanumeric text See following
table
Parameter value
value_objType Alphanumeric text See following
table
Specifies the type of the parameter
groups to be addressed.
value_objName Alphanumeric text See following
table
Name of the specific parameter group
Possible values of the "value_name" parameter
name
value
objType
objName
Description
Power 0, 5.00...33.00 Antenna Antenna01
Antenna02
Antenna03
Antenna04
Radiated power of the antenna
in [dB]
Increment: 0.25 dB
RssiThreshold 0...255 Antenna Antenna01
Antenna02
Antenna03
Antenna04
RSSI threshold value
Transponders with lower RSSI
values are not taken into ac-
count.
This is a value without a unit
and without direct reference to
the power strength.
Polarization Default
Circular
Linear_vertical
Linear_
horizontal
All
Antenna Antenna01
Antenna02
Antenna03
Antenna04
Polarization of the antenna
Currently, this parameter can
only be set for the internal an-
tenna of the RF685R.

Table of Contents

Other manuals for Siemens SIMATIC RF650R

Related product manuals