Service and maintenance
12.2 Error messages
SIMATIC RF650R/RF680R/RF685R
298 Configuration Manual, 03/2018, C79000-G8976-C386-06
0xCD good 1 MISC_ERROR_
TOTAL
• Firmware errors
Possible cause: The firmware update was not run
completely.
• Internal communications error of the communications
module/reader
– Connector contact problem on the communica-
tions module / reader
– Hardware of the communications module / reader
has a defect; → Send in communications module /
reader for repair
– Start "INIT" after correcting the error
• Internal monitoring error of the communications mod-
ule/reader
– Program execution error on the communications
module / reader
– Turn the power supply of the communications
module/reader off and on again
– Start "INIT" after correcting the error
0x61 good 15 NOT_SUPPORTED_
BY_DEVICE
Unknown command
An uninterpretable XML command was sent to the reader
or the Ident profile sends an uninterpretable command to
the reader.
Possible causes:
• The "AdvancedCmd" block was supplied with an in-
correct "CMD".
• The "CMD" input of the "AdvancedCmd" block was
overwritten.
0x63 Bad
Invalid
Argument /
good
5 REGION_NOT_
FOUND_ERROR
All commands:
A parameter of an OPC UA command has an invalid
value.
"ReadTag"/"WriteTag" command:
The addressed memory area is not available in the cur-
0xE1 BadInvalid
-- -- A parameter is missing.
0xE2 BadInvalid
-- -- The parameter has an invalid format.
0xE3 BadInvalid
-- -- The parameter type is invalid.
0xE4 BadInvalid
-- -- Unknown parameter.
The command or the frame has an invalid format.
0xE6 good 1 MISC_ERROR_
TOTAL
The inventory command failed.