Appendix
A.2 Application examples of the algorithms
SIMATIC RF650R/RF680R/RF685R
326 Configuration Manual, 03/2018, C79000-G8976-C386-06
Parameter assignment - S7 / Rockwell user
Follow the steps below to activate the "Black list" algorithm:
1. In the menu item "Settings - Read points" in the "Algorithms" area activate the "Black list"
algorithm.
2. In the "Size" input box, specify the maximum number of transponders that can be
included in the "Black list".
Example A - further procedure
Follow the steps below to include all transponders currently identified (status: OBSERVED),
in the "Black List":
1. Execute the "INVENTORY" command (0x86) to start identification of the transponders.
2. Execute the "EDIT-BLACKLIST" command (0x7A) with the parameter "EDIT_
BLACKLIST_MODE = 0x01" when you are sure that all transponders have been
identified. E.g. at the end of passing through a gate.
3. Execute the "INVENTORY" command (0x87) to end identification of the transponders.
Example B - further procedure
Follow the steps below to add individual transponders selectively to the "Black list":
1. Execute the "EDIT-BLACKLIST" command (0x7A).
2. Specify the block parameters as follows;
– EDIT_ BLACKLIST_MODE = 0x00
– EPCID_ UID ≠0
Enter the EPC-ID of the transponder to be included in the black list.
– LEN_ID ≠0
Enter the EPC-ID length of the transponder to be included in the black list.