You can find detailed information about the status indications in the table below:
Status indicator
Color
Status
Description
RDY
-
Off
24 V control board power supply is missing
Green
Continuously lit
The drive is in "servo on" state
Red
Continuously lit
The drive is in "servo off" state or in the startup state
Flash at 1 Hz
Alarms or faults occurs
Green and
yellow
Flash alternatively at
2 Hz
Drive identification
COM
Green
Continuously lit
PROFINET communication is working with IRT
Flash at 0.5 Hz
PROFINET communication is working with RT
Flash at 2 Hz
Micro SD card/SD card operating (read or write)
Red Continuously lit Communication error (always put the PROFINET communica-
tion error as the first consideration)
Control buttons
Button
Description
Functions
M button
Exits from the current menu
Switches between operating modes in the top level
menu
OK button
Short-pressing:
Confirms selection or input
Enters sub menu
Acknowledges faults
Long-pressing:
Activates auxiliary functions
JOG
Saves parameter set in drive (RAM to ROM)
Sets parameter set to default
Transfers data (drive to micro SD card/SD card)
Transfers data (micro SD card/SD card to drive)
Updates firmware
UP button
Navigates to the next item
Increases a value
JOG in CW (clockwise)
DOWN button
Navigates to the previous item
Decreases a value
JOG in CCW (counter-clockwise)
SHIFT button Moves the cursor from digit to digit for single digit editing,
including the digit of positive/negative sign
Note:
When the sign is edited, "_" indicates positive and "-" indi-
cates negative.
Press the key combination for four seconds to restart the drive
Moves current display to the left page when
is displayed at the upper right corner, for
example .
Moves current display to the right page when
is displayed at the lower right corner, for
example .

Other manuals for Siemens SIMOTICS S-1FL6