Basic operator panel (BOP)
6.5 Auxiliary functions
SINAMICS V90, SIMOTICS S-1FL6
206 Operating Instructions, 04/2019, A5E36037884-007
Adjust AI2 offset
Note
Save parameter
Offset value is set into parameter p29042 (for AI2) or parameter p29061 (for AI1). You must
perform parameter saving after the automatic adjustment of AI offset.
Parameter range
p29042 and p29061 range from
-0.5 V to +0.5 V. A value that is out of this range causes an
alarm.
Refer to chapter "
Parameter list (Page 341)".