Diagnostics
11.2 List of faults and alarms
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2019, A5E36037884-007
401
Fault
Cause
Remedy
F31131: Encoder 1: Deviation
position incremental/absolute
too large
Reaction: ENCODER
Acknowledgement: PULSE
INHIBIT
Absolute encoder
When cyclically reading the absolute
position, an excessively high difference
to the incremental position was detect-
ed. The absolute position that was read
is rejected.
Limit value for the deviation: 15 pulses
(60 quadrants).
Incremental encoder
When the zero is passed, a deviation in
the incremental position was detected.
The first zero mark passed supplies the
reference point for all subsequent
checks. The other zero marks must
have n times the distance referred to
the first zero mark.
Divation in quadrants (1 pulse = 4 quad-
rants).
Check that the encoder cables are routed
in compliance with EMC.
Check the plug connections.
Replace the encoder or encoder cable.
Check whether the coding disk is dirty or
there are strong ambient magnetic fields.
F31150: Initialization error
Reaction: ENCODER
Acknowledgement: PULSE
INHIBIT
Encoder functionality is not operating cor-
rectly.
Check the encoder type used (incremen-
tal/absolute) and the encoder cable.
If relevant, note additional fault messages
that describe the fault in detail.
F52903: Fault inconsistence
between fault status and fault
buffer
Reaction: OFF2
Acknowledgement:
IMMEDIATELY
Fault status and fault number buffer are
inconsistent.
Repower on.
F52904: Control mode
change
Reaction: OFF2
Acknowledgement: POWER
ON
When the control mode is changed, the
drive must be saved and restarted.
Save and restart the drive.
F52911: Positive torque limi-
tation value error
Reaction: OFF2
Acknowledgement:
IMMEDIATELY
One of positive torque limitation values
(p29050, p1520) becomes less than 0.
Configure all of positive torque limitation val-
ues (p29050, p1520) not less than 0.
F52912: Negative torque
limitation value error
Reaction: OFF2
Acknowledgement:
IMMEDIATELY
One of negative torque limitation values
(p29051, p1521) becomes greater than 0.
Configure all of negative torque limitation
values (p29051, 1521) not greater than 0.