SLE / SLE-DP – SIMOLINK Encoder 02.2001 Connections
Siemens AG GWE-477 763 4070.76 J
SIMOVERT MASTERDRIVES Operating Instructions 5-1
5 Connections
The SIMOLINK Encoder has
♦ the X1 sockets for voltage supply,
♦ an encoder interface for signal outputs (X2 on SLE, X21 on SLE-
DP) and
♦ a SIMOLINK fiber-optic cable connection with one transmit socket
and one receive socket.
The SLE-DP module also has socket X22 for the PROFIBUS-DP
connection in compliance with EN 50170.
5.1 Connector X1
The 6-pin connector is on top of the housing. The 24 V power supply to
the SIMOLINK Encoder is connected via X1 (connector type MINI-
COMBICON MC1.5/6-STF-3.81).
M
+24 V
ConnectorSocket X1
Fig. 5-1
Terminal Designation Meaning Range
1n.c.
2n.c.
3n.c.
4n.c.
5 M Ground
6 +24 V 24 V voltage supply +21 ... 28 V
Connectable cross-section: 1.5 mm
2
(AWG 16)
Terminal 1 is the terminal to the rear of the module top plate (see plan view).
Table 5-1 Connector assignments