Procedure, FSF:
Proceed as follows to mount the EMC connecting bracket and the shield plate:
1. If you are using an inverter with an integrated line filter, then mount the EMC connecting
bracket on the shield plate .
On inverters without a filter, the EMC connecting bracket is not included in the scope of
supply of the inverter.
2. Screw the shield module to the inverter using three screws, as shown in the figure.
1P
1P
You have mounted the EMC connecting bracket and the shield plate.
Mounting on a control cabinet panel
Table 4-3 Drilling patterns and mounting equipment, FSAA … FSC
Frame size AA
0.55 kW … 2.2 kW
Frame size A
3.0 kW … 4.0 kW
Frame size B
5.5 kW … 7.5 kW
Frame size C
11 kW … 18.5 kW
Drilling pattern



Drilling pattern with‐
out shield plate
When the shield
plate is mounted,
the drilling pattern
is compatible to
frame size A







Mounting parts 2 × M4 bolts
2 × M4 nuts
2 × M4 washers
3 × M4 bolts
3 × M4 nuts
3 × M4 washers
4 × M4 bolts
4 × M4 nuts
4 × M4 washers
4 x M5 bolts
4 x M5 nuts
4 x M5 washers
Locked-rotor
(starting) torque
2.5 Nm 2.5 Nm 2.5 Nm 2.5 Nm


Installing
4.3 Installing the inverter