Table 4-4 Drilling templates and mounting equipment, FSD … FSF
Frame size D
22 kW … 45 kW
Frame size E
55 kW
Frame size F
75 kW … 132 kW
Drilling pattern







Mounting parts 4 x M5 bolts
4 x M5 nuts
4 x M5 washers
4 x M6 bolts
4 x M6 nuts
4 x M6 washers
4 x M8 bolts
4 x M8 nuts
4 x M8 washers
Locked-rotor
(starting) torque
6 Nm 10 Nm 25 Nm
Mounting on a standard mounting rail (TS 35)
PP
You can mount inverters, frame size
FSAA on a TS 35 standard mounting
rail.
Procedure
Proceed as follows to mount the inverter on a mounting rail:
1. Mount the inverter on the top edge of the mounting rail.
2. Using a screwdriver, actuate the release button on the upper side of the inverter.
3. Continue to actuate the release button until the inverter audibly snaps onto the mounting
rail.


Installing
4.3 Installing the inverter
SINAMICS G120C converter
Operating Instructions, 09/2017, FW V4.7 SP9, A5E34263257B AF 55