11/03 Diagnosis / Faults and Alarms
SINAMICS G150
Operating Manual
10-49
Cause: Checksum error encountered while reading out program memory on TM.
Remedy: - Check whether the permissible ambient temperature has been observed for the TM .
- Replace TM.
A35805 TM: Checksum EPROM not correct
Cause: Internal parameter data corrupted.
Remedy: - Check whether the permissible ambient temperature has been observed for the module.
- Replace module.
A35806 TM: Initialization
Cause: An error occurred on the TM during initialization.
Remedy: none
A35807 TM: Process control Watchdog
Cause: Error timeout Process control on TM
Remedy: Replace TM.
F35820 -
F35825
TM DRIVE-CLiQ: Telegram faulted
Reaction: OFF2
Cause: There is a DRIVE-CLiQ communication error between the control unit and the affected
terminal module.
Remedy: - Check cabinet design and cabling for EMC conformity.
- Replace affected component.
See also: p9916
Acknowl.: Immediate
F35826
F35827
TM DRIVE-CLiQ: fault in cyclic data transfer
Reaction: OFF2
Cause: There is a DRIVE-CLiQ communication error between the control unit and the affected
terminal module.
Remedy: - Check firmware states of affected components.
- Replace Control Unit.
Acknowl.: Immediate
F35828 TM DRIVE-CLiQ: Receive ALARM bit
Reaction: OFF2
Cause: There is a DRIVE-CLiQ communication error between the control unit and the affected
terminal module.
Remedy: Replace affected component.
Acknowl.: Immediate
F35829
F35830
TM DRIVE-CLiQ: Fault in cyclic data transfer
Reaction: OFF2
Cause: There is a DRIVE-CLiQ communication error between the control unit and the affected
terminal module.
Remedy: - Check firmware states of affected components.
- Replace affected component.
See also: p9916
Acknowl.: Immediate
F35831 TM DRIVE-CLiQ: Telegram faulted
Reaction: OFF2
Cause: There is a DRIVE-CLiQ communication error between the control unit and the affected
terminal module.
Remedy: Replace affected component.
Acknowl.: Immediate